TM 11520238T1
4100
Change 5
414 TADS INTERACTIVE FD/LS CHECK (cont)
414
TASK
RESULT
Press and release
MID SHIFT and
MNO/5 keys to
respond with a (N)
(ADC) or (N) key on
CDU (ADD).
The equipment exits the
FD/LS mode and displays the
prompt: TADS GO ANY KEY
FOR FDLS MENUS
4. Perform TADS FLIR operator interactive
a. The following prompt
is displayed on the
HOD: CONTINUE
WITH FULL
SYSTEM TEST (Y)
OR A SYSTEM
TEST (N)?
This prompt is the first of
many prompts to be
displayed and require some
type of operator interaction.
Refer to TM 9-1230-476-20-1
for description of prompts
and any remarks about
prompts.
b. Act upon and
respond to each
prompt as it appears
on the HOD.
If failures are detected,
NOGOs appear on HOD
and the equipment exits
FD/LS testing. Perform
CORRECTIVE ACTION. If no
failure is detected, the TADS
operator interactive test is
exited and HOD displays the
following:
NOTE
If the TADS FLIR has not cooled down the
advisory message FLIR NOT COOLED is
displayed in conjunction with other prompts
(messages).
TADS
GO FLIR NOT COOLED
ANY KEY FOR FDLS
MENUS
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
c. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
5. Restore crew station switch/control settings as follows: