TM 11520238T3
814
818 SIGNAL NAME:
RHE STATUS WORD CHECKSUM ERROR
MEMORY LOCATION: 001270
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of RHE programmable read only memory (PROM).
REMARKS: From RHE to FCC.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 819.
FAIL: Location of fault: replace RHE (TM 9142747520).
819 SIGNAL NAME:
RHE STATUS WORD SUBSYSTEM BUSY
MEMORY LOCATION: 001270
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
BUSY indicates a full 25 hertz (HZ) processing frame has not been completed.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 820.
FAIL: Location of fault: replace RHE (TM 9142747520).
820 SIGNAL NAME:
RHE STATUS MESSAGE SEQUENCE ERROR
MEMORY LOCATION: 001270
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates that all transmit and receive messages are not transferred within any
25 HZ processing frame.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 821.
FAIL: Location of fault: replace RHE (TM 9142747520).
821 SIGNAL NAME:
RHE STATUS FIRE INTERLOCK
MEMORY LOCATION: 001270
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates a fire interlock hangup is detected.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 822.
FAIL: Location of fault: go to paragraph 81.
822 SIGNAL NAME:
RHE STATUS MESSAGE SOFTWARE FAIL
MEMORY LOCATION: 001270
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates an RHE software failure when watchdog timer (250 milliseconds) has
timed out.
REMARKS: From RHE to FCC.
PASS:
If third digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 823.
FAIL: Location of fault: replace RHE (TM 9142747520).