TM 11520238T3
819
843 SIGNAL NAME:
RHE STATUS WORD SUBSYSTEM BUSY
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
BUSY indicates a full 25 HZ processing frame has not been completed.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 844.
FAIL: Location of fault: replace RHE (TM 9142747520).
844 SIGNAL NAME:
RHE STATUS MESSAGE SEQUENCE ERROR
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates that all transmit and receive messages are not transferred within any
25 HZ processing frame.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 845.
FAIL: Location of fault: replace RHE (TM 9142747520).
845 SIGNAL NAME:
RHE STATUS FIRE INTERLOCK
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates a fire interlock hangup is detected.
REMARKS: From RHE to FCC.
PASS:
If second digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 846.
FAIL: Location of fault: replace RHE (TM 9142747520).
846 SIGNAL NAME:
RHE STATUS MESSAGE SOFTWARE FAIL
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates an RHE software failure when watchdog timer (250 milliseconds) has
timed out.
REMARKS: From RHE to FCC.
PASS:
If third digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 847.
FAIL: Location of fault: replace RHE (TM 9142747520).
847 SIGNAL NAME:
RHE STATUS WORD TIMEOUT ERROR
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
FAIL indicates that 100 milliseconds have elapsed without a proper message
from FCC.
REMARKS: From RHE to FCC.
PASS:
If third digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 848.
FAIL: Location of fault: replace RHE (TM 9142747520).