TM 11520238T3
818
Change 4
838 SIGNAL NAME:
RHE STATUS MESSAGE SOFTWARE FAIL
MEMORY LOCATION: 001340
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates an RHE software failure when watchdog timer (250 milliseconds) has
timed out.
REMARKS: From RHE to FCC.
PASS:
If third digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 839.
FAIL: Location of fault: replace RHE (TM 9142747520).
839 SIGNAL NAME:
RHE STATUS WORD TIMEOUT ERROR
MEMORY LOCATION: 001340
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
FAIL indicates that 100 milliseconds have elapsed without a proper message
from FCC.
REMARKS: From RHE to FCC.
PASS:
If third digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 840.
FAIL: Location of fault: replace RHE (TM 9142747520).
840 SIGNAL NAME:
RHE STATUS WORD RHE FAIL (ACY) HARDWARE FAIL (ACZ)
MEMORY LOCATION: 001340
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
FAIL indicates that RHE has failed.
REMARKS: From RHE to FCC.
PASS:
Location of fault if fourth digit displayed is 0: wiring between CPG FCP and RHE.
Troubleshoot wiring to isolate fault (TM 91230476202).
FAIL: Location of fault: replace RHE (TM 9142747520).
841 SIGNAL NAME:
RHE STATUS WORD TERMINAL FLAG (ACY) RHE RECEIVE MSG (ACZ)
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates an error has been detected by RHE DMA controller.
REMARKS: From RHE to FCC.
PASS:
If first digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 849.
FAIL: Location of fault: go to paragraph 843.
842 SIGNAL NAME:
RHE STATUS WORD CHECKSUM ERROR
MEMORY LOCATION: 001372
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of RHE PROM.
REMARKS: From RHE to FCC.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 843.
FAIL: Location of fault: replace RHE (TM 9142747520).