TM 11520238T3
Change 4
8315/(8316 blank)
81206 SIGNAL NAME:
LASER FIRING COMMAND (ACY) LRFD FIRING IND (ACZ)
MEMORY LOCATION: 001444
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates to RHE that TADS laser is firing.
REMARKS: From TADS to RHE.
PASS:
Location of fault if first digit displayed on HOD is 0, 2, 4, or 6: Replace RHE
(TM 91230476201).
FAIL: Location of fault: TADS, wiring from TADS to RHE, RHE. Troubleshoot wiring to isolate fault
(TM 9142747520).