TM 11520238T3
95
915 SIGNAL NAME:
LH FAB MRTU TYPE I STATUS WORD TERMINAL FLAG
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates PASS or FAIL status of MRTU internal selftests.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 923.
FAIL: Location of fault: go to paragraph 916.
916 SIGNAL NAME:
LH FAB MRTU TYPE I STATUS WORD BBC STATUS BIT
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of BBC.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If first digit on HOD is 2 or 6, go to paragraph 917.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
917 SIGNAL NAME:
LH FAB MRTU TYPE I STATUS WORD OUTPUT CLEAR
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates all MRTU outputs are cleared.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If first digit on HOD is 6, go to paragraph 918.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
918 SIGNAL NAME:
LH FAB MRTU TYPE I STATUS DISCRETE OUTPUT BIT
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of 5 VDC discrete outputs.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If second digit on HOD is 1, 3, 5, or 7, go to paragraph 919.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
919 SIGNAL NAME:
LH FAB MRTU TYPE I STATUS DC ANALOG OUTPUT BIT
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates state of output DC analog circuits.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If second digit on HOD is 3 or 7, go to paragraph 920.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).