TM 11520238T3
93
95 SIGNAL NAME:
CPG MRTU TYPE III STATUS DC ANALOG OUTPUT BIT
MEMORY LOCATION: 000566
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of output DC analog circuits.
REMARKS: From CPG MRTU Type III to FCC.
PASS:
If second digit on HOD is 3 or 7, go to paragraph 96.
FAIL: Location of fault: MUX CPG circuit breaker, wiring from MUX CPG circuit breaker to CPG
MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault
(TM 91230476202).
96 SIGNAL NAME:
CPG MRTU TYPE III INPUT BIT STATUS
MEMORY LOCATION: 000566
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of turnon test of input circuitry.
REMARKS: From CPG MRTU Type III to FCC.
PASS:
If second digit on HOD is 7, go to paragraph 97.
FAIL: Location of fault: MUX CPG circuit breaker, wiring from MUX CPG circuit breaker to CPG
MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault
(TM 91230476202).
97 SIGNAL NAME:
CPG MRTU TYPE III AD BIT STATUS
MEMORY LOCATION: 000566
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of analog to digital converter.
REMARKS: From CPG MRTU Type III to FCC.
PASS:
If third digit on HOD is 1, go to paragraph 98.
FAIL: Location of fault: MUX CPG circuit breaker, wiring from MUX CPG circuit breaker to CPG
MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault
(TM 91230476202).
98 SIGNAL NAME:
CPG MRTU TYPE III SERIAL DIGITAL ERROR
MEMORY LOCATION: 000566
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors data entry keyboard (DEK) and alphanumeric display (AND).
REMARKS: From CPG MRTU Type III to FCC.
PASS:
If fourth digit on HOD is 0, go to paragraph 99.
FAIL: Location of fault: go to Chapter 17, paragraph 173.
99 SIGNAL NAME:
CPG MRTU TYPE III SERIAL DIGITAL ERROR
MEMORY LOCATION: 000620
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors AND.
REMARKS: From CPG MRTU Type III to FCC.
PASS:
If fourth digit on HOD is 0, go to paragraph 910.
FAIL: Location of fault: go to Chapter 15, paragraph 1527.