TM 11520238T3
1526
15105 SIGNAL NAME:
AND L4 CHAR 8 7
MEMORY LOCATION: 000632
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 7 and 8 on line 4.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15106.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
15106 SIGNAL NAME:
AND L4 CHAR 10 9
MEMORY LOCATION: 000631
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 9 and 10 on line 4.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15107.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
15107 SIGNAL NAME:
AND L4 CHAR 12 11
MEMORY LOCATION: 000630
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 11 and 12 on line 4.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15108.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
15108 SIGNAL NAME:
AND L4 CHAR 14 13
MEMORY LOCATION: 000627
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 13 and 14 on line 4.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15109.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
15109 SIGNAL NAME:
AND L4 CHAR 16 15
MEMORY LOCATION: 000626
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 15 and 16 on line 4.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15110.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).