TM 11520238T3
1523
1590 SIGNAL NAME:
AND L3 CHAR 2 1
MEMORY LOCATION: 000651
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 1 and 2 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1591.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1591 SIGNAL NAME:
AND L3 CHAR 4 3
MEMORY LOCATION: 000650
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 3 and 4 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1592.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1592 SIGNAL NAME:
AND L3 CHAR 6 5
MEMORY LOCATION: 000647
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 5 and 6 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1593.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1593 SIGNAL NAME:
AND L3 CHAR 8 7
MEMORY LOCATION: 000646
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 7 and 8 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1594.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1594 SIGNAL NAME:
AND L3 CHAR 10 9
MEMORY LOCATION: 000645
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 9 and 10 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1595.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).