TM 11520238T3
1524
1595 SIGNAL NAME:
AND L3 CHAR 12 11
MEMORY LOCATION: 000644
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 11 and 12 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1596.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1596 SIGNAL NAME:
AND L3 CHAR 14 13
MEMORY LOCATION: 000643
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 13 and 14 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1597.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1597 SIGNAL NAME:
AND L3 CHAR 16 15
MEMORY LOCATION: 000642
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 15 and 16 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1598.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1598 SIGNAL NAME:
AND L3 CHAR 18 17
MEMORY LOCATION: 000641
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 17 and 18 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1599.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1599 SIGNAL NAME:
AND L3 CHAR 20 19
MEMORY LOCATION: 000640
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 19 and 20 on line 3.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 15100.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).