TM 11520238T3
206
2010 SIGNAL NAME:
DOP EASTING
MEMORY LOCATION: 000453
MEMORY DATA BIT(S):
118
(HEX)
CONDITION:
If second digit displayed on HOD is 0 or 1, and third digit is 0 or 4=0
If second digit displayed on HOD is 2 or 3, and third digit is 0 or 4=1
If second digit displayed on HOD is 4 or 5, and third digit is 0 or 4=2
If second digit displayed on HOD is 6 or 7, and third digit is 0 or 4=3
If second digit displayed on HOD is 0 or 1, and third digit is 2 or 5=4
If second digit displayed on HOD is 2 or 3, and third digit is 1 or 5=5
If second digit displayed on HOD is 4 or 5, and third digit is 1 or 5=6
If second digit displayed on HOD is 6 or 7, and third digit is 1 or 5=7
If second digit displayed on HOD is 0 or 1, and third digit is 2 or 6=8
If second digit displayed on HOD is 2 or 3, and third digit is 2 or 6=9
SIGNAL FUNCTION:
Indicates ones field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2011.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2011 SIGNAL NAME:
DOP EASTING
MEMORY LOCATION: 000453
MEMORY DATA BIT(S):
74
(HEX)
CONDITION:
If first digit displayed on HOD is 0, and second digit is 0, 2, 4, or 6=0
If first digit displayed on HOD is 1, and second digit is 0, 2, 4, or 6=1
If first digit displayed on HOD is 2, and second digit is 0, 2, 4, or 6=2
If first digit displayed on HOD is 3, and second digit is 0. 2. 4, or 6=3
If first digit displayed on HOD is 4, and second digit is 0, 2, 4, or 6=4
If first digit displayed on HOD is 5, and second digit is 0, 2, 4, or 6=5
If first digit displayed on HOD is 6, and second digit is 0, 2, 4, or 6=6
If first digit displayed on HOD is 7, and second digit is 0, 2, 4, or 6=7
If first digit displayed on HOD is 0, and second digit is 1, 3, 5, or 7=8
If first digit displayed on HOD is 1, and second digit is 1, 3, 5, or 7=9
SIGNAL FUNCTION:
Indicates tenths field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2012.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
