TM 11520238T3
208
2015 SIGNAL NAME:
DOP NORTHING 99.99/+99.99 KM
MEMORY LOCATION: 000457
MEMORY DATA BIT(S):
1918
(BINARY)
CONDITION:
If sixth digit displayed on HOD is 0, and fifth digit is 0, 1, 2, or 3=plus, north, west, up,
to
If sixth digit displayed on HOD is 0, and fifth digit displayed is 4, 5, 6, or 7=failure
warning
If sixth digit displayed on HOD is 1, and fifth digit is 0, 1, 2, or 3=no computed data and
no failure detected
If sixth digit displayed on HOD is 1, and fifth digit is 4, 5, 6, or 7=minus, south, east,
down, from
SIGNAL FUNCTION:
Indicates sign/status of Doppler.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2016.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2016 SIGNAL NAME:
DOP NORTHING
MEMORY LOCATION: 000457
MEMORY DATA BIT(S):
1512
(HEX)
CONDITION:
If third digit displayed on HOD is 0, 1, 2, or 3, and fourth digit is 0=0
If third digit displayed on HOD is 4, 5, 6, or 7, and fourth digit is 0=1
If third digit displayed on HOD is 0, 1, 2, or 3, and fourth digit is 1=2
If third digit displayed on HOD is 4, 5, 6, or 7, and fourth digit is 1=3
If third digit displayed on HOD is 0, 1, 2, or 3, and fourth digit is 2=4
If third digit displayed on HOD is 4, 5, 6, or 7, and fourth digit is 2=5
If third digit displayed on HOD is 0, 1, 2, or 3, and fourth digit is 3=6
If third digit displayed on HOD is 4, 5, 6, or 7, and fourth digit is 3=7
If third digit displayed on HOD is 0, 1, 2, or 3, and fourth digit is 4=8
If third digit displayed on HOD is 4, 5, 6, or 7, and fourth digit is 4=9
SIGNAL FUNCTION:
Indicates tens field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2017.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).
2017 SIGNAL NAME:
DOP NORTHING
MEMORY LOCATION: 000457
MEMORY DATA BIT(S):
118
(HEX)
CONDITION:
If second digit displayed on HOD is 0 or 1, and third digit is 0 or 4=0
If second digit displayed on HOD is 2 or 3, and third digit is 0 or 4=1
If second digit displayed on HOD is 4 or 5, and third digit is 0 or 4=2
If second digit displayed on HOD is 6 or 7, and third digit is 0 or 4=3
If second digit displayed on HOD is 0 or 1, and third digit is 2 or 5=4
If second digit displayed on HOD is 2 or 3, and third digit is 1 or 5=5
If second digit displayed on HOD is 4 or 5, and third digit is 1 or 5=6
If second digit displayed on HOD is 6 or 7, and third digit is 1 or 5=7
If second digit displayed on HOD is 0 or 1, and third digit is 2 or 6=8
If second digit displayed on HOD is 2 or 3, and third digit is 2 or 6=9
SIGNAL FUNCTION:
Indicates ones field.
REMARKS: From Doppler through CPG MRTU Type III to FCC.
PASS:
If CONDITION agrees with heading, go to paragraph 2018.
FAIL: Location of fault: Doppler, wiring from Doppler to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 111520238232).