TM 11520238T3
256
2518 SIGNAL NAME:
PNVS PWR SW
MEMORY LOCATION: 001555
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Sets pilot night vision sensor (PNVS) to ON.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If first digit displayed on HOD is 0, 2, 4, or 6, go to Chapter 10, paragraph 102.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).