TM 11520238T3
Change 4
253
254 SIGNAL NAME:
CONTRAST ADJ
MEMORY LOCATION: 001104
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD while increasing CONTRAST; memory location response should increase
when CONTRAST is increased and decrease when CONTRAST is decreased.
SIGNAL FUNCTION:
Adjusts IHADSS contrast.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION has been met, go to Chapter 7, paragraph 733.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
255 SIGNAL NAME:
ACM SW
MEMORY LOCATION: 001117
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Selects optimum gain and level of night vision sensors.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If fourth digit displayed on HOD is 0, 1, 4, or 5, go to Chapter 10, paragraph 1025.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
256 SIGNAL NAME:
IHADSS BRSIT SW (ACY) PLT IHAD BST SW1 (ACZ)
MEMORY LOCATION: 001117
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Enables IHADSS boresighting.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If fourth digit displayed on HOD is 1, 3, 5, or 7, go to Chapter 7, paragraph 736.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
257 SIGNAL NAME:
PLT/CPG VIDEO SW (ACY) PLT VIDEO SEL SW (ACZ)
MEMORY LOCATION: 001120
MEMORY DATA BIT(S):
8
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Selects pilot or CPG video.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If second digit displayed on HOD is 4, 5, 6, or 7, go to Chapter 7, paragraph 744.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).
258 SIGNAL NAME:
PLT GRAY SCALE SW
MEMORY LOCATION: 001120
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Selects gray scale for helmet mounted display (HMD) calibration.
REMARKS: From pilot FCP through LH FAB MRTU Type I to FCC.
PASS:
If fourth digit displayed on HOD is 0, 1, 4, or 5, go to Chapter 15, paragraph 1563.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type
I. Troubleshoot wiring to isolate fault (TM 91230476202).