TM 1-1520-238-T-4
4114
433.
PILOT COLLECTIVE STICK DOES NOT RESET CHOP FUNCTION
433
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68F
Aircraft Electrician
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200, R200 panels
removed
Pilot seat removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between:
J107R and P977A1,
J107N and P977A2,
J107J and P978A1,
J107G and P978A2.
Does open exist?
YES
Repair open wire.
(Engine 1) Go to
paragraph 412.
(Engine 2) Go to
paragraph 413.
NO
Go to step 2.
2. With pilot collective stick grip in RUN position,
check for open between:
P107K and P107R,
P107K and P107J,
P107L and P107N,
P107L and P107G.
Does open exist?
YES
Replace pilot collective stick
(TM 1-1520-238-23).
NO
Replace start mode relay panel
(TM 1-1520-238-23).
END OF TASK