TM 1-1520-238-T-4
4118
436.
ENGINE 2 DOES NOT ACCELERATE TO OR REMAIN BETWEEN 23% AND 25% NG
436
IN IGN OVRD (cont)
8. Check for open between:
J2224 and P978A16,
P978A13 and P439A11.
(A402):
J21A11 and TB28F,
J21A14 and TB28A.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Go to step 9.
9. Check for 28 VDC at (A76)J1X.
Is voltage present?
YES
Go to step 10.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station).
10. Check for open between:
P463X and P173V,
P173W and P978B2.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Replace pilot power quadrant
(TM 1-1520-238-23).
11. Check for 28 VDC at (A402)TB28A.
Is voltage present?
YES
Go to step 13.
NO
Go to step 12.
12. Check for open between:
P463c and P439A14.
(A402):
J21A14 and TB28A.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station)
13. Check for open between P978A13 and
(A402)TB28F.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Replace start mode relay panel
(TM 1-1520-238-23).
END OF TASK