4119
437.
ENG START CIRCUIT BREAKER DOES NOT STAY CLOSED (WITH ENG START NO 2
437
SWITCH IN START POSITION)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68F
Aircraft Electrician
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P978. Set and hold ENG START
NO 2 switch in START position. Check for short
between P463X and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 2.
2. With grounding strap attached, check for short
between (A330)J2A14 and ground.
Does short exist?
YES
Replace start mode relay panel
(TM 1-1520-238-23).
NO
Go to step 4.
3. Check for short between P173H and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 413.
NO
Replace pilot power quadrant
(TM 1-1520-238-23).
4. Check for short between P978B3 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 413.
NO
Replace turbine starter switch
(TM 1-1520-238-23).
END OF TASK