ENG START ENG 2 INDICATOR REMAINS LIGHTED ABOVE 52% NG
439
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 panel removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With MASTER IGNITION SWITCH to ON, set
and hold ENG START NO 2 switch to IGN
OVRD. Check for 1
0.1 VAC between P64L
and P64M.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for open between:
P64M and P365,
P64L and P363.
Does open exist?
YES
Repair open wire between:
P64L and J448A18,
P64M and J448A17,
P448A18 and J2228,
P448A17 and J2229,
P2228 and P363,
P2229 and P365.
Go to paragraph 412.
NO
Replace air turbine starter
(TM 1-1520-238-23).
3. Place ENG START NO 2 switch to OFF. Check
for short between P2225 and P2226.
Does short exist?
YES
Replace engine starter air
pressure regulator valve
(TM 1-1520-238-23).
NO
Go to step 4.
4. Temporarily install replacement turbine speed
cutout switch and go to paragraph 412.
Does problem still exist?
YES
Replace flow turbine start switch
(TM 1-1520-238-23).
NO
Replace turbine speed cutout
switch (TM 1-1520-238-23).
END OF TASK