456.
ECS AIRFLOW PRESENT WITH ENG START NO 2 SWITCH AT IGN OVRD
456
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68F
Aircraft Electrician
One person to assist
References:
TM 1-1520-238-T-8
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 panel removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place MASTER IGN switch to ON. Set and hold
ENG START NO 2 switch to IGN OVRD. Check
for 28 VDC at (A402)XK47X1.
Is voltage present?
YES
Go to step 4.
NO
Go to step 2.
2. Check for open between (A402):
TB210G and J20B10,
XK47X1 and TB210J.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Go to step 3.
3. Check for open between P433B10 and
P977A16.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Replace start mode relay panel
(TM 1-1520-238-23).
4. Remove relay (A402)K47
(TM 1-1520-238-23). Check for open between
(A402)XK47X2 and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Go to step 5.
5. Set and hold ENG START NO 2 switch to IGN
OVRD. Check for 28 VDC at
(A402)XK29/10X1.
Is voltage present?
YES
Go to step 6.
NO
Repair open wire between
(A402):
XK47X1 and TB210H.
Go to paragraph 413.
6. Check for open between (A402)XK29/10X2
and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 413.
NO
Go to step 7.
7. Attach relay (A402)K47
(TM 1-1520-238-23), detach wire from
(A402)XK47A2. Set and hold ENG START
NO 2 switch to IGN OVRD. Check for
28 VDC in (A402)XK47A2.
Is voltage present?
YES
Replace relay (A402)K47
(TM 1-1520-238-23).
NO