TM 1-1520-238-T-4
4144
456.
ECS AIRFLOW PRESENT WITH ENG START NO 2 SWITCH AT IGN OVRD (cont)
456
8. Detach wire from (A402)XK29/10A2. Set and
hold ENG START NO 2 switch to IGN OVRD,
check for 28 VDC at (A402)XK29/10A2.
Is voltage present?
YES
Replace relay (A402)K29/10
(TM 1-1520-238-23).
NO
Refer to TM 1-1520-238-T-8 to
troubleshoot ECS.
END OF TASK