TM 1-1520-238-T-5
7105
728.
OIL BYP UTIL HYD INDICATOR IS LIGHTED
728
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check utility hydraulic manifold pressure dirty
filter indicator.
Is indicator retracted?
YES
Go to step 2.
NO
Replace utility hydraulic
manifold pressure strainer
(TM 1-1520-238-23).
2. Check utility hydraulic manifold return dirty filter
indicator.
Is indicator retracted?
YES
Go to step 3.
NO
Replace utility hydraulic
manifold return strainer
(TM 1-1520-238-23).
3. Check for short between P1870 and ground.
Does short exist?
YES
Go to step 4.
NO
Replace pilot caution/warning
panel (TM 1-1520-238-23).
4. Detach P238, check for short between P1870
and ground.
Does short exist?
YES
Repair shorted wire between:
P1870 and J436A5,
P436A5 and P238 SP1,
P238 SP1 and P2387,
P238 SP1 and P23819.
Go to paragraph 721.
NO
Go to step 5.
5. Check for continuity between (HP2):
J118 and J119.
Does continuity exist?
YES
Replace utility hydraulic
manifold pressure dirty filter
indicator (TM 1-1520-238-23).
NO
Go to step 6.
6. Check for continuity between (HP2):
J17 and J117.
Does continuity exist?
YES
Replace utility hydraulic
manifold return dirty filter
indicator (TM 1-1520-238-23).
NO
Go to step 7.
7. Check for short between (HP2)J119 and
chassis ground.
Does short exist?
YES
Go to step 8.
NO
Go to step 9.