TM 1-1520-238-T-5
7108
730.
EMERGENCY HYDRAULIC PRESSURE INDICATOR EDGELIGHT IS NOT LIGHTED
730
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check LT PRI circuit breaker.
Does circuit breaker stay closed ?
YES
Go to step 2.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
2. Check for 5 VDC between P746A and P746B.
Is voltage present?
YES
Replace emergency hydraulic
pressure indicator
(TM 1-1520-238-23).
NO
Go to step 3.
3. Check for 5 VDC between (A326):
J16B5 and J16B6.
Is voltage present?
YES
Repair open wire between:
P746B and P480B5,
P746A and P480B6.
Go to paragraph 721.
NO
Go to step 4.
4. Check for 5 VDC between (A326):
TB131D and TB132D.
Is voltage present?
YES
Go to step 5.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
5. Check for resistance between (A326):
R41 and R43.
Is resistance present?
YES
Repair open wire between
(A326):
J16B5 and R41,
J16B6 and TB132D,
R43 and TB131D.
Go to paragraph 721.
NO
Replace resistor (A326)R4
(TM 1-1520-238-23).
END OF TASK