TM 1-1520-238-T-5
7124
742.
EMERGENCY HYDRAULIC PRESSURE INDICATOR DOES NOT INDICATE 3000 PSI
742
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Hydraulic system
leak check
completed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at P2389.
Is voltage present?
YES
Go to step 2.
NO
Repair open wire between
(A402)TB29J and P2389,
or replace (A402)TB29.
Go to paragraph 721.
2. Check for open between P23810 and ground.
Does open exist?
YES
Repair open wire between
P23810 and GS630C.
Go to paragraph 721.
NO
Go to step 3.
3. Verify AGPU pressure for 3000 psi
(TM 1-1520-238-23). Check for 4.2 VDC at
P746C and P746D.
Is voltage present?
YES
Replace emergency hydraulic
pressure indicator
(TM 1-1520-238-23).
NO
Go to step 4.
4. Check for open between:
P746C and P23824,
P746D and P23823.
Does open exist?
YES
Repair open wire.
Go to paragraph 721.
NO
Go to step 5.
5. Remove emergency hydraulic pressure
transducer (TM 1-1520-238-23). Check for open
between (HP2):
J19 and J8D,
J110 and J8C,
J123 and J8B,
J124 and J8A.
Does open exist?
YES
Replace utility hydraulic
manifold (TM 1-1520-238-23).
NO
Replace emergency hydraulic
pressure transducer
(TM 1-1520-238-23).
END OF TASK