EMERGENCY HYDRAULIC FLIGHT CONTROLS DO NOT FUNCTION PROPERLY
744
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check EMERG HYD circuit breaker.
Is circuit breaker closed?
YES
Go to step 2.
NO
Go to paragraph 743.
2. Set EMERG HYD switch to EMERG HYD.
Check for 28 VDC at P23813.
Is voltage present?
YES
Go to step 3.
NO
Go to step 5.
3. Check for open between P2384 and GS631B.
Does open exist?
YES
Repair open wire.
Go to paragraph 721.
NO
Go to step 4.
4. Remove utility hydraulic manifold override
solenoid (TM 1-1520-238-23). Check for open
between (HP2):
J113 and J4A,
J14 and J4D.
Does open exist?
YES
Replace utility hydraulic
manifold (TM 1-1520-238-23).
NO
Replace utility hydraulic
manifold override solenoid
(TM 1-1520-238-23).
5. Check for 28 VDC at P527A7.
Is voltage present?
YES
Go to step 6.
NO
Go to step 7.
6. Check for open between J527A7 and P23813.
Does open exist?
YES
Repair open wire.
Go to paragraph 721.
NO
Replace pilot EMERG HYD
switch S2.
Go to paragraph 721.
7. Check for 28 VDC at (A76)J1K.
Is voltage present?
YES
Repair open wire between
P463K and P527A7.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station).
END OF TASK