TM 1-1520-238-T-5
7126
743.
EMERG HYD CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
743
8. Check for short between (A331)S22 wire ends
and ground.
Does short exist?
YES
Repair shorted wire between:
P1907 and P527A6,
J527A6 and (A331)S22.
Go to paragraph 721.
NO
Replace pilot EMERG HYD
pressure switch
(TM 1-1520-238-23).
9. Check for short between (HP2)J111 and
chassis ground.
Does short exist?
YES
Go to step 10.
NO
Go to step 12.
10. Remove utility hydraulic pressure transducer
(TM 55152023823). Check for short between
(HP2)J111 and chassis ground.
Does short exist?
YES
Replace utility hydraulic
manifold (TM 1-1520-238-23).
NO
Replace utility hydraulic
pressure transducer
(TM 1-1520-238-23).
11. Detach wire at (A402)TB29J. Check for short
between P463m and ground.
Does short exist?
YES
Repair shorted wire between:
P463m and P441A2,
P441A5 and P2396.
(A402):
J24A2 and TB29K,
TB29L and J24A5.
Go to paragraph 721.
NO
Repair shorted wire between:
P442A3 and P23811,
P238 SP2 and P2389.
(A402):
TB29J and J5A3.
Go to paragraph 721.
12. Remove emergency hydraulic pressure
transducer (TM 1-1520-238-23). Check for short
between (HP2)J19 and chassis ground.
Does short exist?
YES
Replace utility hydraulic
manifold (TM 1-1520-238-23).
NO
Replace emergency hydraulic
pressure transducer
(TM 1-1520-238-23).
END OF TASK