TM 1-1520-238-T-5
880
814.
CPG EMERG BATT ENG INST CIRCUIT BREAKER DOES NOT STAY CLOSED
814
(HELICOPTERS WITH CPG DIM/TEST PANEL INSTALLED)
Tools:
Nomenclature
Part Number
Tool Kit, Aircraft
SC518099CLA01
Mechanics
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
67R
Attack Helicopter Repairer
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open CPG EMERG BATT ENG INST circuit
breaker. Check for short between (A77):
J18 and ground,
J110 and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station)
NO
Go to step 2.
2. Detach P401. Check for short between:
P7668 and ground,
P76610 and ground.
Does short exist?
YES
Go to step 3.
NO
Replace SDC
(TM 1-1520-238-23).
3. Detach P1093. Check for short between:
P7668 and ground,
P76610 and ground.
Does short exist?
YES
Repair shorted wire between:
P7668 and P401 SP1,
P76610 and P401 SP2,
P40157 and P401 SP1,
P40158 and P401 SP2,
P109320 and P401 SP1,
P109321 and P401 SP2.
Go to paragraph 810.
NO
Replace CPG ENG INST
dimmer power supply
(TM 1-1520-238-23).
END OF TASK