TM 1-1520-238-T-5
Change 7
885
819.
PILOT TORQUE INDICATOR DOES NOT INDICATE FULL SCALE OR SHOW DIGITAL 888
819
OR VERTICAL SCALE INDICATORS HAVE EVERY OTHER LAMP NOT LIGHTED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot dim/test panel, set and hold
DGT OFF/NORM/TST switch to TST. Check for
short between P6617 and ground.
Does short exist?
YES
Go to step 2.
NO
Repair open wire between:
P6617 and (A326)TB150H.
Go to paragraph 810.
2. Check for 2 to 5 VDC at P667 and P668.
Is voltage present?
YES
Go to step 3.
NO
Go to step 6.
3. Check for:
5 VDC at P6612,
8 VDC at P6613,
8 VDC at P6614.
Are voltages present?
YES
Go to step 4.
NO
Go to step 5.
4. Check for open between:
P669 and GS427F,
P6610 and GS427G,
P6611 and GS251M.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace pilot TORQUE indicator
(TM 1-1520-238-23).
5. Check for open between:
P6612 and P40117,
P6613 and P40110,
P6614 and P4012.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
6. Check for open between:
P667 and P40129,
P668 and P40135.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
END OF TASK