TM 1-1520-238-T-5
888
822.
PILOT ENGRTR RPM% INDICATOR DOES NOT INDICATE FULL SCALE OR VERTICAL
822
SCALE INDICATORS HAVE EVERY OTHER LAMP NOT LIGHTED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot dim/test panel, hold
DGT OFF/NORM/TST switch to TST. Check for
short between P6517 and ground.
Does short exist?
YES
Go to step 2.
NO
Repair open wire between:
P6517 and (A326)TB150G.
Go to paragraph 810.
2. Check for 2 to 5 VDC at P657 and P658.
Is voltage present?
YES
Go to step 3.
NO
Go to step 6.
3. Check for:
8 VDC at P6513,
8 VDC at P6514.
Does open exist?
YES
Go to step 4.
NO
Go to step 5.
4. Check for open between:
P659 and GS427H,
P6510 and GS427J,
P6511 and GS427K.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace pilot ENGRTR
RPM% indicator
(TM 1-1520-238-23).
5. Check for open between:
P6513 and P4009,
P6514 and P4001.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
6. Check for open between:
P657 and P40025,
P658 and P40031.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
END OF TASK