TM 1-1520-238-T-5
8106
838.
ALL CPG DIGITAL READOUTS REMAIN LIGHTED (CPG DGT OFF/NORM/TST SWITCH
838
SET TO DGT OFF)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between:
P109215 and P753,
P109215 and P7424.
Does open exist?
YES
Repair open wire between:
P109215 and P75 SP1,
P753 and P75 SP1,
P7424 and P75 SP1.
Go to paragraph 810.
NO
Go to step 2.
2. Check for open between:
P10924 and GS245E.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace CPG dim/test panel
(TM 1-1520-238-23).
END OF TASK