TM 1-1520-238-T-5
Change 7
8111
843.
CPG TORQUE INDICATOR DOES NOT INDICATE FULL SCALE OR SHOW DIGITAL 888 OR 843
VERTICAL SCALE INDICATORS HAVE EVERY OTHER LAMP NOT LIGHTED
(HELICOPTERS WITHOUT CPG DIM/TEST PANEL INSTALLED)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L40 cover removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check CPG TORQUE indicator.
Are both vertical displays and digital
readouts blanked out?
YES
Go to step 3.
NO
Go to step 2.
2. With test switch on CPG SDD panel depressed,
check for open between P7417 and ground.
Does open exist?
YES
Repair open wire between:
P7417 and P73 SP1.
Go to paragraph 810.
NO
Go to step 3.
3. Check for open between:
P749 and ground,
P7410 and ground,
P7411 and ground.
Does open exist?
YES
Repair open wire between:
GS245A and P749,
GS245B and P7410,
GS255C and P7411,
Go to paragraph 810.
NO
Go to step 4.
4. Check CPG TORQUE indicator for voltages as
follows:
P747 for 2 to 5 VDC,
P748 for 2 to 5 VDC,
P7412 for 5 VDC,
P7413 for 8 VDC,
P7414 for 8 VDC.
Are voltages present?
YES
Replace CPG TORQUE
indicator (TM 1-1520-238-23).
NO
Go to step 5.
5. Check for open between:
P747 and P40126,
P748 and P40132,
P7412 and P40120,
P7413 and P4019,
P7414 and P4011.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
END OF TASK