TM 1-1520-238-T-5
8110
Change 2
842.
ALL CPG ENGINE INSTRUMENT VERTICAL SCALE INDICATORS AND DIGITAL
842
READOUTS ARE BLANK (WITH CPG DIM/TEST PANEL INSTALLED)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC between:
P109320 and P109328,
P109321 and P109329.
Is voltage present?
YES
Replace CPG ENG INST
dimmer power supply
(TM 1-1520-238-23).
NO
Repair open wire between:
P109320 and P401 SP1,
P109321 and P401 SP2,
P109328 and GS371K,
P109329 and GS371L.
Go to paragraph 810.
END OF TASK