TM 1-1520-238-T-6
998
97.
SYSTEM DESCRIPTION (cont)
97
PILOT CENTER
CIRCUIT BREAKER
PANEL
LT UTIL SEC
CB23
LT PRI
CB39
28 VDC
PILOT EXT LT / INTR LT
PANEL
115 VAC
MULTI - CHANNEL
DIMMING
CONTROLLER
0 - 5 VDC
0 - 5 VDC
PILOT AFT
CIRCUIT BREAKER
PANEL
ON
OFF
0 - 5 VDC
EDGE LT
PNL
SWITCH
PILOT CENTER
CIRCUIT BREAKER
PANEL
PILOT FORWARD
CIRCUIT BREAKER
PANEL
CPG CIRCUIT
BREAKER
PANEL 1
PRI LT
CB14
EMERG BATT UTIL
SEC LT
CB29
115 VAC
28 VDC
0 - 5 VDC
0 - 5 VDC
PILOT
MATRIX
MODULE
CPG INTR LT PANEL
CPG
CIRCUIT BREAKER
PANEL 1
CPG
CIRCUIT BREAKER
PANEL 2
0 - 5 VDC
M69-371
Figure 990.
Edge-Lighting Circuit Breakers Functional Block Diagram
(12) Pilot Station DC Ground Circuit Protection System.
The pilot station dc ground circuit protection
system (fig. 991) saves weight by eliminating large portions of heavy wiring, reduces cost, maintains a constant
load voltage due to parallel circuitry, and protects the IR jammer. When power is applied to the IR jammer, current
flows from ground through IR JAM PWR circuit breaker (CB63) to the RCCB. Current flows from contact 3 of the
RCCB through the coil to contact A1 energizing the RCCB. When the RCCB is energized, the dc bus is connected
to the dc load. When an overload condition occurs, the current through the IR JAM PWR circuit breaker (CB63)
increases, opening the IR JAM PWR circuit breaker (CB63). When the IR JAM PWR circuit breaker (CB63) is
opened, the RCCB deenergizes removing the load from the dc bus.
A1
A2
3
5A
28 VDC LOAD
DC
BUS
RCCB
A1
A2
3
5A
28 VDC LOAD
DC
BUS
RCCB
IR
JAM PWR
CB63
MISSION
RDR
JAM DC
CB72
CB2
CB1
M69-369
Figure 991.
Pilot Station DC Ground Circuit Protection System Interface Diagram