TM 1-1520-238-T-6
9454
9199. CIRCUIT PROTECTION SYSTEM (AC ESSENTIAL BUS 2 CPG STATION)
9199
MAINTENANCE OPERATIONAL CHECK (cont)
NOTE
Refer to pilot station (fig. 9167) and CPG station (fig. 9168) for
configuration and component locations.
If referenced out of one paragraph or volume into another for additional
troubleshooting, upon completion of the task, return to the maintenance
operational check for the original paragraph or volume.
1. Perform the maintenance operational check as follows:
Task
Result
a. On CPG circuit breaker panel 1 (fig. 9169),
check that the following circuit breakers are
closed:
AWS MTR (CB3),
AWS AMMO (CB7),
PRI LT (CB14),
FC RCDR (CB8).
If AWS MTR circuit breaker (CB3) does not stay
closed, go to paragraph 9201.
If AWS AMMO circuit breaker (CB7) does not stay
closed, go to paragraph 9202.
If PRI LT circuit breaker (CB14) does not stay closed,
go to paragraph 9203.
If FC RCDR circuit breaker (CB8) does not stay
closed, go to paragraph 9204.
M69-213
PRI LT
AWS
AMMO
AWS
MTR
FC
RCDR
Figure 9169.
CPG Circuit Breaker Panel 1