TM 1-1520-238-T-6
9458
9202. AWS AMMO CIRCUIT BREAKER (CB7) DOES NOT STAY CLOSED OR CONTINUITY
9202
DOES NOT EXIST BETWEEN (A77): J4-H AND J2-1, J4-B AND J2-15, J4-E AND J2-22
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 9-1090-208-23-2
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does AWS AMMO circuit breaker (CB7) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB7. Set BATT/EXT PWR switch to OFF.
Check for short between (A77):
J2-1 and ground,
J2-15 and ground,
J2-22 and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 9-1090-208-23-2 to
troubleshoot area weapon
system.
3. Detach wires at CB7-A2, CB7-B2, and CB7-C2.
Check for short between (A77):
J2-1 and ground,
J2-15 and ground,
J2-22 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 9199.
NO
Replace AWS AMMO circuit
breaker (CB7)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB7-A1 and CB3-A1,
CB7-B1 and CB3-B1,
CB7-C1 and CB3-C1,
CB7-A2 and (A77)J2-1,
CB7-B2 and (A77)J2-15,
CB7-C2 and (A77)J2-22.
Does open exist?
YES
Repair open wire.
Go to paragraph 9199.
NO
Replace AWS AMMO circuit
breaker (CB7)
(TM 1-1520-238-23).
END OF TASK