TM 1-1520-238-T-6
9460
9204. FC RCDR CIRCUIT BREAKER (CB8) DOES NOT STAY CLOSED OR CONTINUITY
9204
DOES NOT EXIST BETWEEN (A77): J4-E AND J2-16
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 11-1520-238-23-2
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does FC RCDR circuit breaker (CB8) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB8. Set BATT/EXT PWR switch to OFF.
Check for short between (A77)J2-16 and
ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 11-1520-238-23-2
to troubleshoot video recorder
system.
3. Detach wire at CB8-2. Check for short between
(A77)J2-16 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 9199.
NO
Replace FC RCDR circuit
breaker (CB8)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB8-1 and CB7-A1,
CB8-2 and (A77)J2-16.
Does open exist?
YES
Repair open wire.
Go to paragraph 9199.
NO
Replace FC RCDR circuit
breaker (CB8)
(TM 1-1520-238-23).
END OF TASK