TM 1-1520-238-T-6
9492
Change 1
9222. SHORT EXISTS BETWEEN P4J OR P4G AND GROUND
9222
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
Paragraph 9148
All dc essential bus 2 pilot
station circuit breakers
open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for short between P4-G and ground.
Does short exist?
YES
Go to step 2.
NO
Go to step 5.
2. Detach wire end at CB56-1. Check for short
between P4-G and ground.
Does short exist?
YES
Repair shorted wire between
CB56-1 and P4-G.
Go to paragraph 9220.
NO
Go to step 3.
3. Attach CB56 wire and detach wire end at
CB59-1. Check for short between P4-G and
ground.
Does short exist?
YES
Replace bus bar between CB56
and CB59, and check for foreign
material (TM 1-1520-238-23).
NO
Go to step 4.
4. Attach CB59 wire and detach wire ends at
CB73-1. Check for short between P4-G and
ground.
Does short exist?
YES
Repair shorted wire between
CB59-1 and CB73-1.
Go to paragraph 9220.
NO
Repair shorted wire between
CB79-1 and CB73-1.
Go to paragraph 9220.
5. Detach wire at CB46-1. Check for short between
P4-J and ground.
Does short exist?
YES
Repair shorted wire between
CB46-1 and P4-J.
Go to paragraph 9220.
NO
Go to step 6.
6. Attach wire CB46-1 and detach wire end at
CB91-1. Check for short between P4-J and
ground.
Does short exist?
YES
Repair shorted wire between:
CB46-1 and CB66-1,
CB49-1 and CB89-1.
Go to paragraph 9220.
NO
Repair shorted bus bar between
CB89-1 and CB91-1, and check
for foreign material
(TM 1-1520-238-23).
END OF TASK