Task
Result
k. Attach P1, P5, and P463. Check that all pilot
emergency battery circuit breakers are
closed.
l. On pilot ELEC PWR panel, set BATT/EXT
PWR switch in EXT PWR.
m. Check that all pilot dc emergency bus circuit
breakers (fig. 9191) remain closed.
If JETT circuit breaker (CB34) does not stay closed,
go to paragraph 9270.
If ENG WARN circuit breaker (CB52) does not stay
closed, go to paragraph 9271.
If FUEL APU circuit breaker (CB9) does not stay
closed, go to paragraph 9272.
If FUEL VLV ACTR circuit breaker (CB14) does not
stay closed, go to paragraph 9273.
If FIRE EXTGH APU circuit breaker (CB26) does not
stay closed, go to paragraph 9274.
If FIRE EXTGH CPG circuit breaker (CB15) does not
stay closed, go to paragraph 9275.
If FIRE EXTGH PLT circuit breaker (CB25) does not
stay closed, go to paragraph 9276.
If FIRE DETR APU circuit breaker (CB11) does not
stay closed, go to paragraph 9277.
If FIRE DETR ENG 2 circuit breaker (CB13) does not
stay closed, go to paragraph 9278.
If FIRE DETR ENG 1 circuit breaker (CB12) does not
stay closed, go to paragraph 9279.
If ENG INST circuit breaker (CB17) does not stay
closed, go to paragraph 9280.
If ENG START circuit breaker (CB58) does not stay
closed, go to paragraph 9281.
If ENG LVR circuit breaker (CB16) does not stay
closed, go to paragraph 9282.
If FUEL XFEED circuit breaker (CB55) does not stay
closed, go to paragraph 9283.
If ENG CUT circuit breaker (CB60) does not stay
closed, go to paragraph 9284.
If THROT circuit breaker (CB8) does not stay closed,
go to paragraph 9285.
If STBY ATTD circuit breaker (CB19) does not stay
closed, go to paragraph 9286.
If RDR ALT circuit breaker (CB31) does not stay
closed, go to paragraph 9287.