TM 1-1520-238-T-6
9550
9263. CIRCUIT PROTECTION SYSTEM (DC EMERGENCY BUS PILOT STATION)
9263
MAINTENANCE OPERATIONAL CHECK(CONT)
Task
Result
Step m. (cont)
If TRIM circuit breaker (CB87) does not stay closed,
go to paragraph 9288.
If EMERG HYD circuit breaker (CB35) does not stay
closed, go to paragraph 9289.
If LT UTIL SEC circuit breaker (CB23) does not stay
closed, go to paragraph 9290.
If LT CAUT circuit breaker (CB21) does not stay
closed, go to paragraph 9291.
If LT SRCH/LDG CONTR circuit breaker (CB80) does
not stay closed, go to paragraph 9292.
If LT SRCH/LDG circuit breaker (CB22) does not stay
closed, go to paragraph 9269.
If CHAFF circuit breaker (CB48) does not stay closed,
go to paragraph 9293.
If RTR BRK circuit breaker (CB37) does not stay
closed, go to paragraph 9294.
If RDR WARN circuit breaker (CB53) does not stay
closed, go to paragraph 9295.
If PITOT HTR circuit breaker (CB36) does not stay
closed, go to paragraph 9296.
If COMM ICS circuit breaker (CB27) does not stay
closed, go to paragraph 9297.
If COMM VHF FM circuit breaker (CB64) does not
stay closed, go to paragraph 9298.
If COMM KY-28 circuit breaker (CB30) does not stay
closed, go to paragraph 9299.
If COMM UHF AM circuit breaker (CB24) does not
stay closed, go to paragraph 9300.
If COMM IFF circuit breaker (CB29) does not stay
closed, go to paragraph 9301.
If COMM ADF circuit breaker (CB65) does not stay
closed, go to paragraph 9302.
If APU HOLD circuit breaker (CB10) does not stay
closed, go to paragraph 9266.
If FUEL FILL circuit breaker (CB32) does not stay
closed, go to paragraph 9267.
If ECS CAB circuit breaker (CB76) does not stay
closed, go to paragraph 9303.