9263. CIRCUIT PROTECTION SYSTEM (DC EMERGENCY BUS PILOT STATION)
9263
MAINTENANCE OPERATIONAL CHECK(CONT)
Task
Result
ag. On pilot ELEC PWR panel (fig. 9190), set
BATT/EXT PWR switch to OFF and detach
P463.
ah. On pilot ELEC PWR panel, set BATT/EXT
PWR switch to EXT PWR.
ai. Check for 28 VDC at (A76):
J1-U and J1-W.
If 28 VDC is not present, go to
paragraph 9290.
aj. Check for 28 VDC at (A76)J1-V.
If 28 VDC is not present, go to
paragraph 9292.
ak. Check for 28 VDC at (A76)J1-y.
If 28 VDC is not present, go to
paragraph 9291.
al. Check for 28 VDC at (A76)J1-t.
If 28 VDC is not present, go to
paragraph 9293.
am. Check for 28 VDC at (A76)J1-n.
If 28 VDC is not present, go to
paragraph 9294.
an. Check for 28 VDC at (A76)J1-q.
If 28 VDC is not present, go to
paragraph 9295.
ao. Check for 28 VDC at (A76)J1-s.
If 28 VDC is not present, go to
paragraph 9296.
ap. Check for 28 VDC at (A76)J1-a.
If 28 VDC is not present, go to
paragraph 9297.
aq. Check for 28 VDC at (A76)J1-w.
If 28 VDC is not present, go to
paragraph 9298.
ar. Check for 28 VDC at (A76)J1-p.
If 28 VDC is not present, go to
paragraph 9299.
as. Check for 28 VDC at (A76)J1-v.
If 28 VDC is not present, go to
paragraph 9300.
at. Check for 28 VDC at (A76)J1-S.
If 28 VDC is not present, go to
paragraph 9301.
au. Check for 28 VDC at (A76)J1-r.
If 28 VDC is not present, go to
paragraph 9302.
av. Check for 28 VDC at P1-2.
If 28 VDC is not present, go to
paragraph 9303.
aw. Check for 28 VDC at P1-32.
If 28 VDC is not present, go to
paragraph 9283.
3. On pilot ELEC PWR panel (fig. 9190), set BATT/EXT PWR switch to OFF.
4. Perform EXTERNAL POWER POWER DOWN (para 946).