TM 1-1520-238-T-6
9646
Change 4
9333. PILOT CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL
9333
CHECK (cont)
1. Perform the maintenance operational check as follows:
Task
Result
a. On pilot center circuit breaker panel
(fig. 9213), check that LT CAUT circuit
breaker (CB21) is closed.
If LT CAUT circuit breaker (CB21) does not stay
closed, go to paragraph 9335.
b. On pilot EXT LT/INTR LT panel (fig. 9213),
place INST control to BRT.
If pilot caution/warning edgelighted panel is not
lighted, go to paragraph 9336A.
M69-304
INST CONTROL
LT CAUT
Figure 9213.
Pilot Center Circuit Breaker and EXT LT/INTR LT Panels
c. On pilot master caution/warning panel
(fig. 9214), check that PRESS TO TEST
indicator is lighted.
If PRESS TO TEST indicator is not lighted, replace
lamp (TM 1-1520-238-23). If lamp still does not light,
go to paragraph 9336.
MASTER
CAUTION
INDICATOR
LOW RPM
ROTOR
INDICATOR
APU FIRE
INDICATOR
ENGINE 1
OUT
INDICATOR
ENGINE
CHOP
INDICATOR
ENGINE 2
OUT
INDICATOR
HIGH RPM
INDICATOR
BUCS
FAIL
INDICATOR
PRESS
TO TEST
INDICATOR
M69-305
Figure 9214.
Pilot Master Caution/Warning Panel