TM 1-1520-238-T-6
9698
9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9364
M69-334
CPG ARM / SAFE
SWITCH
RKT
SWITCH
GUN
SWITCH
MSL
SWITCH
FCC MUX
SWITCH
MUX PRI / SEC
SWITCH
TADS
SWITCH
PLT / GND
ORIDE SWITCH
Figure 9234.
CPG FIRE CONTROL Panel
Task
Result
m. On CPG FIRE CONTROL panel
(fig. 9234), place RKT switch to NORM. On
CPG ORT (fig. 9236), hold weapon action
switch (WAS) to RKT. On CPG
caution/warning panel (fig. 9232), check
that ROCKET indicator is lighted.
If CPG ROCKET indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9386.