TM 1-1520-238-T-6
9748
9395. AUDIO WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9395
1. PILOT STABILATOR MANUAL CONTROL PANEL
2. PILOT POWER QUADRANT
3. PILOT ELEC PWR PANEL
4. PILOT AFT CIRCUIT BREAKER PANEL
5. PILOT CENTER CIRCUIT BREAKER PANEL
6. PILOT MASTER CAUTION / WARNING PANEL
6
2
3
4
5
1
M69-337
Figure 9237.
Pilot Station
1. CPG CIRCUIT BREAKER PANEL 1
2. CPG STABILATOR MANUAL CONTROL PANEL
3. CPG MASTER CAUTION / WARNING PANEL
4. CPG CAUTION / WARNING PANEL
1
2
3
4
M69-338
Figure 9238.
CPG Station
1. Perform the maintenance operational check as follows:
Task
Result
a. On pilot circuit breaker panel (fig. 9239),
check that ENG WARN (CB52), COMM ICS
(CB27), STAB AUTO AC (CB2), STAB
AUTO DC (CB3), STAB MAN DC (CB6),
and STAB MAN AC (CB7) circuit breakers
are closed.
If ENG WARN circuit breaker (CB52) does not stay
closed, go to paragraph 9397.
If COMM ICS circuit breaker (CB27) does not stay
closed, refer to TM 11-1520-238-23-2 to troubleshoot
intercommunication system.
If STAB AUTO AC (CB2), STAB AUTO DC (CB3),
STAB MAN DC (CB6), and STAB MAN AC (CB7)
circuit breakers do not stay closed, refer to
TM 1-1520-238-T-7 to troubleshoot stabilator.