b. On CPG circuit breaker panel 1 (fig. 9240),
check that EMERG BATT ICS circuit
breaker (CB13) is closed.
If EMERG BATT ICS circuit breaker (CB13) does not
stay closed, refer to TM 11-1520-238-23-2 to
troubleshoot intercommunication system.
M69-340
EMERG BATT ICS
Figure 9240.
CPG Circuit Breaker Panel 1
c. On pilot ELEC PWR panel (fig. 9241), set
BATT/EXT PWR switch to OFF and back to
EXT PWR. Check that audio warning is
heard in pilot and CPG headsets.
If audio warning is not heard in both headsets, go to
paragraph 9398.
If audio warning is heard in one but not the other
headset, refer to TM 11-1520-238-23-2 to