TM 1-1520-238-T-7
10186
Change 5
1064. CPG FUEL XFER ADVISORY LIGHT IS NOT LIGHTED (ADA)
1064
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L40 door removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between P747M and P747N.
Does open exist?
YES
Go to step 4.
NO
Go to step 2.
2. Check for 28 VDC at P747P.
Is voltage present?
YES
Replace multichannel dimming
controller
(TM 1-1520-238-23).
NO
Go to step 3.
3. Check for open between P747P and P179B8.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Replace pilot FUEL panel
(TM 1-1520-238-23).
4. Check for open between:
P747M and DS18 SP1,
P747N and DS18 SP2.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Replace CPG FUEL XFER
advisory light (DS18)
(TM 1-1520-238-23).
END OF TASK