TM 1-1520-238-T-7
Change 5
10188.1
1066A.
PILOT GREEN FUEL XFR INDICATOR IS NOT LIGHTED WITH PILOT
1066A
TRANS SWITCH SET AT TO AFT (ADB)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28VDC at P429A18.
Is voltage present?
YES
Go to step 2.
NO
Go to step 6.
2. Check for open between (A402):
XK59X1 and J23A18,
XK59X2 and TB333C,
XK59A1 and J23A15,
XK59A2 and TB333A,
TB333B and GS8D.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Go to step 3.
3. Check for open between P429A15 and
P174B7.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Go to step 4.
4. Check open for between (A131):
J1B7 and J2A10.
Does open exist?
YES
Replace pilot FUEL panel
(TM 1-1520-238-23).
NO
Go to step 5.
5. Check open for between:
P179A10 and P1893.
Does open exist?
YES
Repair open wire between:
P179A10 and J914A11,
P914A11 and P1893.
Go to paragraph 1047.
NO
Replace relay (A402)K59
(TM 1-1520-238-23).
6. Check open for between P429A18 and
P174B8.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Replace pilot FUEL panel
(TM 1-1520-238-23).
END OF TASK