TM 1-1520-238-T-7
10195
1070. NITROGEN INERT MONITOR INDICATOR IS NOT ALL BLACK (OK) WITH UNIT
1070
OPERATING
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. In aft avionics bay, reset NITROGEN INERT
MONITOR indicator.
Does indicator trip to black (OK) and white
(FAIL)?
YES
Go to step 2.
NO
Go to paragraph 1067.
2. Check for 28 VDC at J436B20.
Is voltage present?
YES
Go to step 4.
NO
Go to step 3.
3. Check for 720 70 ohms resistance between
(A335):
L471 and L472.
Is resistance present?
YES
Repair shorted wire between:
P436B20 and (A335)L472,
J436B20 and P10855,
P436B19 and (A335)L471,
J436B19 and P10856.
Go to paragraph 1067.
NO
Replace NITROGEN INERT
MONITOR indicator
(TM 1-1520-238-23).
4. Remove pressurized air and electrical power.
Replace filter element in NIU
(TM 1-1520-238-23). Apply electrical power and
pressurized air. Reset indicator.
Does indicator trip to black (OK) and white
(FAIL)?
YES
Go to step 5.
NO
Go to paragraph 1067.
5. Check for open between P10857 and P10858.
Does open exist?
YES
Replace NIU
(TM 1-1520-238-23).
NO
Go to step 6.
6. Check for open between (A335):
S901 and S902.
Does open exist?
YES
Repair open wire between:
P436B18 and (A335)S902,
J436B18 and P10857,
P436B17 and (A335)S901,
J436B17 and P10856.
Go to paragraph 1067.
NO
Replace NITROGEN INERT
MONITOR indicator
(TM 1-1520-238-23).