TM 1-1520-238-T-7
10196
1071. NITROGEN INERT MONITOR INDICATOR IS NOT BLACK (OK) AND WHITE
1071
(FAIL) WHEN PRESS TO TEST SWITCH IS DEPRESSED FOR 10 SECONDS
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door opened,
R200 panel removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With PRESS TO TEST button on NITROGEN
INERT MONITOR indicator depressed, check for
open between P436B17 and P436B18.
Does open exist?
YES
Go to step 2.
NO
Go to step 3.
2. With PRESS TO TEST button on NITROGEN
INERT MONITOR indicator depressed, check for
open between (A335):
S901 and S902.
Does open exist?
YES
Replace NIU
(TM 1-1520-238-23).
NO
Repair open wire between:
P436B17 and (A335)S90 SP1,
P436B18 and (A335)S90 SP2.
Go to paragraph 1067.
3. Check for continuity between (A335):
L471 and L472.
Does continuity exist?
YES
Go to step 4.
NO
Replace NITROGEN INERT
MONITOR indicator
(TM 1-1520-238-23).
4. Check for open between:
P10855 and (A335)L472,
P10856 and (A335)L471,
P10857 and J436B18,
P10858 and J436B17.
Does open exist?
YES
Repair open wire.
Go to paragraph 1067.
NO
Replace NIU
(TM 1-1520-238-23).
END OF TASK