TM 1-1520-238-T-7
10193
1068. NITROGEN INERTING SYSTEM WIRING INTERCONNECT DIAGRAM
1068
K1-C1
K1-B1
K1-A1
J16-E
J16-F
J16-B
(NOTE 3)
RECEPTACLE
SERVICE UTILITY
AND GROUND
EXTERNAL POWER
AC ELECTRICAL
POWER GENERATION
SYSTEM
(NOTE 3)
115 VAC
P/O UTILITY RECEPTACLE CIRCUIT BREAKER BOX
NITROGEN
CB94
5A
T3
10A
A1
A2
T3
B1
B2
C1
C2
A3
INERT
UTIL PWR
AC ELEC
CB6
B20
P1085
J1
B19
B18
B17
J436
SP2(M)
SP1(M)
BITE
INDICATOR
L47 (NOTE 1)
NITROGEN INERT MONITOR INDICATOR
S90
SP2(M)
SP1(M)
(NOTE 4)
-
+
1
2
SWITCH S90
(NOTE 2)
GS442
5
2
1
P436
A146
IN
TEST
IND OUT
BITE
LO
HI
P1085
J1
NIU
6
7
8
B
A335
2
L47
1
RED
PRESS TO TEST
BLK
S90
L47
W118
W668
W118
P
W118
W102
W118
W655
ØC
ØB
ØA
ØB
115
VAC
ØB
P
NOTES:
1. GIVES AUTOMATIC VISUAL INDICATION AT FAILURE OF NIU.
2. USED TO CHECK OPERATION OF AUTOMATIC FAULT DETECTION CIRCUITS IN NITROGEN INERTING.
3. ELECTRICAL SYSTEM (TM 1-1520-238-T-6).
4. M DESIGNATES A SOFT SPLICE WHICH MAY BE DISCONNECTED FOR WIRING CHECK.
1
2
M70-006A
SHEET 1 OF 1