TM 1-1520-238-T-7
10224
1079. REFUEL VALVE OPEN INDICATOR ON PILOT CAUTION/WARNING PANEL IS
1079
NOT LIGHTED WITH REFUEL VALVE SWITCH SET TO OPEN
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-4
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provision
R160 door open
TM 1-1520-238-T-4
Maintenance headset
connected
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot master caution/warning panel, press
PRESS TO TEST indicator.
Is REFUEL VALVE OPEN indicator lighted?
YES
Go to step 2.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot master
caution/warning system.
2. Check for open between:
P1876 and (A402)K34A2,
(A402)K34X1 and (A402)J31A4,
(A402)K34X2 and ground,
P444A4 and P2607,
P2513 and P2607.
Does open exist?
YES
Repair open wire.
Go to paragraph 1076.
NO
Go to step 3.
3. Check resistance between (A402):
K34X1 and K34X2.
Is resistance 316 10 ohms?
YES
Replace refueling panel
(TM 1-1520-238-23).
NO
Replace relay (A402)K34
(TM 1-1520-238-23).
END OF TASK