TM 1-1520-238-T-7
11164
1123. DASE MAINTENANCE OPERATIONAL CHECK
1123
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-1
TM 1-1520-238-T-3
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 and L200
access panels
removed
Flight control system
inspection
Paragraph 610
DASE/STABILATOR
POWER UP completed
1. Perform DASE FD/LS check (TM 1-1520-238-T-1).
NOTE
If a descrepancy is noted during the FD/LS check, perform corrective action
indicated in TM 1-1520-238-T-1. If the descrepancy still exists after
performing the corrective action required, refer to the following listed
failure symptoms and perform troubleshooting.
If CPG DIR LVDT NO-GO CPG COMPARTMENT
appears on heads out display (HOD), refer to
TM 1-1520-238-T-3, DASE Multiplex Read Codes,
and perform troubleshooting. Then, if no fault is
found, go to paragraph 1155 and perform
troubleshooting.
If DASE COMPUTER NO-GO AFT AVIONICS BAY
appears on HOD, refer to TM 1-1520-238-T-3, DASE
Multiplex Read Codes, and perform troubleshooting.
Then, if no fault is found, go to paragraph 1157 and
perform troubleshooting.
If CPG COLLECTIVE LVDT NO-GO CPG
COMPARTMENT appears on HOD, refer to
TM 1-1520-238-T-3, DASE Multiplex Read Codes,
and perform troubleshooting. Then, if no fault is
found, go to paragraph 1158 and perform
troubleshooting.